L2/IF |
Specifications |
|
Type | DIB Direct Mount DP Manifold Pipe to Flange (Isolate Isolate Vent) |
Inlets | Female 1/2" NPT |
Outlets | Flanged 'O'-Ring Transmitter Hook-Up |
Packing | PTFE Graphite |
M.C.W.P. Pressure | 6000 psi / 10000 psi |
Temperature Range | -30°C (-22°F) to 215°C (420°F) PTFE -30°C (-22°F) to 440°C (824°F) Graphite |
Weight | 0.89 kg |
2 Way Direct Mount DIB Manifold |
The L2/IF manifold mounts directly to standard pressure transmitters. It utilizes the Isolate Isolate Vent pattern which allows double isolaion of the process side. Great cost benefits are achieved due to the elminiation of multi valve systems. The manifold is supplied with the transmitter seals as standard, with the bolting kit being included as and option added to the part number. |
Features |
|